ACCESS DOORS: A hinged or detached cover provided with a hand operated fastening device where accessibility is required.
Typically it is interlocked using a key interlock system to prevent access to the ESP when the ESP is energized.
ACFM: Actual Cubic Feet per Minute of gas volume at the actual condition temperature, pressure and composition. See gas flow
rate.
ACID DEW POINT: The temperature at which combustion gases are saturated with sulfuric acid.
AIR LOAD: This term refers to energizing the ESP during an outage period at ambient temperatures. The object is to verify the
electrical integrity of the bus section, to obtain electrical readings of voltage and current and to determine whether sparkover
occurs before reaching a specific limit of the TR Set rating. The advantage of this type of measurement is to relate the internal
integrity of the ESP BUS SECTIONS to one another as to electrode damage or extent of ash buildup.
These readings can be obtained with or without fan operation, or at different temperatures but, all conditions should be recorded.
Measurements can be recorded as maximum readings or as V-I CURVES. Generally, SPARKOVER should not be observed during
these readings.
ALIGNMENT: This term refers to the maintenance of optimum clearances between the high voltage system and the grounded
surfaces of the precipitator. Operation at the highest possible ESP voltages depends to a large measure on good mechanical
integrity and elimination of reduced distances where sparkover could occur. This means the high voltage frame of a BUS SECTION
must be held plum relative to the grounded collecting surfaces. Ideally, discharge electrodes should be centered in the gas
passages between the collecting plate surfaces, and centered between the vertical ribs / baffles of the collecting plates. On a
practical basis for the 9″ (228mm) wide GAS PASSAGES commonly found in WEIGHTED WIRE ESP designs, proper alignment
generally means no corona producing wire closer than 4″ (102mm) to the flat surface of the collector plate or 5 1/2″ (140mm) to
any vertical rib of the collector plate. The emitters, or corona producing elements of RIGID DISCHARGE ELECTRODES in GAS
PASSAGES spaced at 12″ (305mm) should generally be within 1/2″ of center (51/2″, 140mm) of the flat surface of the collecting
plates, and be a minimum of 6″ – 71/2″ (152 – 190mm) to any vertical rib of the collector plate. Allowable tolerances will vary
somewhat by manufacturer, electrode design, and from a practical standpoint, by age and condition of the ESP.
ANODE: Positive electrical terminal of high voltage power supply; this is the collecting plate surface (ash surface) which is
ANTI-SWAY INSULATOR: These insulators are used to prevent the bottom high voltage frames, which position and retain the
DISCHARGE ELECTRODES, from swinging or drifting out of alignment. The insulators are either a ceramic bar or a shaft type and are
usually secured to the hopper wall. Some designs connect directly between the collecting plates and the lower high voltage frames.
ANTI-SNEAKAGE BAFFLES: Internal baffle elements within the precipitator to prevent the gas from bypassing the active field or
some internal mechanical defect. A poor AUTOMATIC VOLTAGE CONTROL circuit, as well as operation of the control in the
MANUAL MODE, can aggravate this problem. Meter swings are usually 2 to 3 times greater those than observed during normal
ASPECT RATIO: The ratio obtained by dividing effective length of the precipitator by the effective height.
AUTOMATIC MODE: Modern controls will often feature the ability to transfer from an automatic mode of AUTOMATIC VOLTAGE
CONTROL, which is normal operation, to a MANUAL MODE for maintenance or trouble periods. The automatic mode allows the TR
AUTOMATIC VOLTAGE CONTROL: The normal method of controlling the amount of secondary current to the ESP is by controlling
the magnitude of voltage on the primary winding of the TR Set. This is accomplished by detecting the transient disruption in the
electrical circuitry caused by sparkover, or an arc, in the ESP. A feedback circuit then adjusts the gate signal of an SCR (thyristor) so
BACK CORONA: A term that signifies that the ash layer on the collector surface has reached a level of RESISTIVITY that produces a
flow of positive IONS back towards the negative high voltage discharge electrode. Most commonly observed back corona
SEVERE BACK CORONA (generically referred to as back corona and also referred to as reverse ionization), this condition is
extremely detrimental to precipitator performance and will result in dramatic re-entrainment of material for the collecting plates
BACT (Best Available Control Technology): An emission limitation based on the maximum degree of emission reduction
achievable. Under Title I of the CAAA, EPA will establish BACT standards for serious, severe and extreme non-attainment areas.
BALANCED DRAFT: The condition where the absolute pressure in a boiler furnace is exactly equal to the absolute atmospheric
BUS SECTION: Is the smallest portion of high voltage structure, containing a fixed group of DISCHARGE ELECTRODES that can be
independently energized by a single Transformer (TR). More than one bus section can be controlled through a TR either in parallel
or series arrangement.
CASING: The precipitator shell or casing is designed to confine the flue gas within a specific collection zone, and it must provide
structural support for the discharge and collecting electrode systems, rapping systems, gas distribution system, and other
precipitator components. The precipitator casing is usually constructed of fabricated steel panels fitted with external columns,
beams, and stiffeners and is designed so that the final assembly provides a gas tight unit able to withstand both internal and
external loading. The precipitator casing includes ACCESS DOORS located in the side walls and on the roof that permit access to
the precipitator interior. A key interlock system prevents opening the doors while the precipitator is energized. Access walkways,
platforms, stairs, and ladders are attached to the casing at various internal and external locations.
CATHODE: This is the negative polarity, high voltage DISCHARGE ELECTRODE of a precipitator. It is the cathode that suffers metal
erosion due to ESP repetitive sparkover “ a common cause of localized wire thinning, draw-out due to weight tension, and ultimate
CELLS: A cell is an arrangement of bus sections across the width of the ESP. Typically the number of cells times the number of fields
CFM: Cubic Feet (of any gaseous matter) per Minute. See gas flow rate.
CHAMBER: Refers to a gas tight longitudinal subdivision of the precipitator (a precipitator without any internal dividing walls is a
single chamber precipitator; a precipitator with a single internal dividing wall is a two chamber precipitator, etc.). Very wide
precipitators may have non gas tight load bearing walls that are used for structural purposes. Technically these non gas tight walls
CHEVRON DESIGN: Refers to the inlet transition design that places 2 parallel ESPs at a small angle to each other. This layout
CLR (Current Limiting Reactor): This is primarily a ballast of inductance placed in the low voltage circuit to provide current limiting
ability under sparkover in the ESP. Another major advantage of a properly sized reactor is to better shape the waveform of the
input voltage to the TR Set thereby gaining a greater conduction angle of secondary current flow. This feature has benefits for ash
COLLECTION EFFICIENCY: The weight of dust collected per unit time divided by the weight of dust entering the precipitator during
COLLECTING SURFACE: Is the term for the sheet metal collector plate that serves as the point of deposition for the particulate that
is negatively charged within the gas passage of the ESP. Collecting surface plate design differs between manufacturers but, all are
secured to the shell of the ESP at ground potential and serve as the positive anode of the gas passage.
COLD SIDE ESP: An ESP which is installed downstream of the air heaters
COLLECTION SURFACE AREA: The total flat projected area of collecting surface exposed to the active electrostatic field (length x
each half cycle, out of an available 8.33 milliseconds, (60 Hz), represents the length of time this current flows relative to the off
time of the CYCLE. Operating at the current rating of the TR Set usually means a conduction angle of 86% exists. As the operating
level of the TR Set is reduced, this angle decreases in a somewhat linear fashion.
CONTROL EQUIPMENT: The necessary electrical components required to regulate the potential of the high voltage system by
regulating the voltage or current applied to the primary of the high voltage transformer (also metering and protection equipment,
and controls for auxiliary electrical items such as rappers, heaters, etc.).
CONTROL CABINET: This cabinet contains the control and monitor apparatus of the power supply. Features mainly involve low
voltage breaker, overload controls, metering, and the automatic voltage control components.
CORONA: A gaseous discharge found near an ESP discharge electrode resulting in a faint glow caused by ionization of gas
CORONA CURRENT: This term signifies all the measured current flow passing from the CORONA DISCHARGE of the DISCHARGE
ELECTRODE through the gas space of the ESP to ground, for a collecting plate area controlled by a single TR Set. It is also commonly
known as the secondary DC current and is read on the SECONDARY AMMETER either as milliamperes or fraction of an amp.
CORONA DISCHARGE: This term represents an electrical breakdown of the flue gas at localized small zones on the surface of the
DISCHARGE ELECTRODE. Approximately 20 – 25 thousand volts is required to start this process on a smooth 0.1″ (2.54mm)
diameter wire. Corona onset will vary with electrode design and gas passage spacing. Electrons coming out of this localized tuft of
activity primarily produce the negative gas IONS required to properly charge the ash particles negatively so they can migrate
CORONA POWER (KW): The product of secondary current and secondary voltage. Power density is generally expressed in terms of:
(1) watts per square foot of collecting surface, or (2) watts per 1000 ACFM of gas flow.
CURRENT DENSITY: The amount of secondary current per unit of ESP collecting surface. Common units are ma/ft 2 and nA/cm2.
CURRENT WAVE SHAPE: Usually refers to the pattern of the pulsating secondary CORONA CURRENT as observed on an
oscilloscope. As conduction angles decrease, the waveshape tends toward peakiness. As conduction angles increase, the wave
CYCLE: Generally refers to an alternating current of 60 cycles per second which is the standard energizing mode of the TR Sets. This
means that 3600 alternating cycles per minute are rectified into 7200 half cycles per minute and are fed into the area of the
DEW POINT: The temperature at which the equilibrium vapor pressure of a liquid is equal to the existing partial pressure of the
respective vapor. (For air containing water vapor, it is the temperature at which liquid water begins to condense for a given state
of humidity and pressure as the temperature is reduced. For flue gaining water vapor and SO it is the set of conditions at which
space is concerned.
DISCHARGE ELECTRODE: Refers to the high voltage component which ionizes the process gases and creates the electric field. It is
shaped to provide a corona discharge when the impressed voltage breaks the gas down at the electrode surface. This breakdown
of the gas creates corona tufts on the discharge surface. Typically, voltage applied to the discharge electrode is of negative polarity.
In many WEIGHTED WIRE designs, the discharge electrode is a smooth round wire slightly larger than 0.1″ (2.54mm) in diameter.
Barbed wire is also frequently used in part, or all of the ESP, to enhance corona characteristics. Discharge Electrodes of the RIGID
and RIGID FRAME or Mast variety are also widely available. They can vary widely in style and shape
DEUTSCH-ANDERSON EQUATION: The Deutsch-Anderson Equation is a mathematical formula that can be used to determine the
collection efficiency of an ESP. It states that efficiency is related to the ratio of collecting area (A) divided by the gas volume (V)
multiplied by the particle migration velocity (w). This formula is the basis for all ESP design and performance models.
Collection Efficiency N = 1 – e “ (A / V) w
DUST or MIST CONCENTRATION: The weight of dust or mist contained in a unit of gas, e.g. pounds per thousand pounds of gas,
grains per actual cubic foot of gas, or grains per standard dry cubic foot (the temperature and pressure of the gas must be specified
if given as volume).
ELECTRONIC TUBE RECTIFIER: A rectifier consisting of high vacuum rectifier tubes. Can be either Air-cooled or Liquid-immersed.
ELECTROSTATIC PRECIPITATOR (ESP): A single precipitator is defined by all parts that are contained by an independent casing.
EXCEEDANCE: Defined as a condition that is detected by the CAM plan monitoring that provides data in terms of an emissions
limitation or standard and that indicates that emissions (or opacity) are greater than the applicable emissions standard, consistent
EXCESS AIR: Air in excess of the amount necessary to combust all the available fuel.
EXCURSION: Defined as a departure from an indicator or indicator range established for monitoring under the CAM plan,
FIELD: Refers to an arrangement of one or more bus sections, oriented perpendicular to the direction of flue gas flow, which is
energized by one TR SET. The number of TR sets / power supplies positioned in series (parallel to the gas flow), each one
controlling the collection of particles in a specific area, will typically identify the number of fields of a precipitator.
FLY ASH: Particulate matter entrained in the flue gas stream leaving a fossil fuel fired boiler. It consists of both ash and
combustible matter.
FOSSIL FUELS: Coal, oil and natural gas; so-called because they are the remains of ancient plant and animal life.
FULL WAVE: This electrical term means that the 7200 rectified half cycles per minute are fed into the full precipitator area
FUME: Solid particulates generated by condensation from the gaseous state, generally after volatilization from molten metal, and
often accompanied by a chemical reaction, such as oxidation. Fumes flocculate and sometime coalesce.
GAS DISTRIBUTION DEVICES: Internal elements in the transition or ductwork to produce the desired velocity contour at the inlet
and outlet face of the precipitator example: turning vanes or perforated plates.
GAS FLOW RATE, CUBIC FEET PER MINUTE (CFM): The volume of process gas at any point of the plant exhaust system measured in
ACFM (Actual Cubic Feet Per Minute): The actual gas flow measured.
SCFM (Standard Cubic Feet Per Minute): The gas flow volume reduced to 70OF (standard temperature) by calculation.
DSCFM (Dry Standard Cubic Feet Per Minute): The gas flow reduced to 70O (standard temperature) and without volume of
GAS PASSAGE: Is the passage formed by two adjacent collector plates, normally on 9″ – 10″ (228 – 254mm) centers with
WEIGHTED WIRE systems; 11″ – 16″ (279-406mm) with Rigid Discharge and Rigid Frame Electrode systems. The passage can be
considered to consist of two capacitors with the negative DISCHARGE ELECTRODE at centerline and the positive ground collecting
plates forming the other electrode. This passage is where the action takes place within the precipitator.
GAS VELOCITY: A figure obtained by dividing the volume rate of gas flow through the precipitator by the effective cross-sectional
area of the precipitator. Gas velocity is generally expressed in terms of ft./sec. And is computed as follows:
Effective cross-section is construed to be the effective field height X width of gas passage X number of passages.
GRAIN: A dust weight unit commonly used in air pollution control. Equal to one seven thousandth of a pound. One grain = 1/7000
lb.
GRAIN LOADING: The rate at which particles are emitted form a pollution source. Measurement is made by the number of grains
precipitator are receiving alternate pulses or 3600 rectified half cycles per minute. The TR Set will always have two outlet bushings
with this mode of hook-up. Even though each bus section operates electrically independent, the overall operating level of the TR
Set is controlled by the weakest point of the areas controlled. On balance, with the larger TR Sets in use today, the half-wave mode
HIGH VOLTAGE BUS SYSTEM: The high voltage (HV) bus system is used to transfer power from the power supplies (Transformer
Rectifiers) to the HV discharge electrode frames. The bus is the conductor and is usually made of pipe/bar, cable, or a combination
of the two. Bus runs between the interlocked insulator compartments or penthouses are enclosed in watertight bus duct. The bus
is supported with insulators, usually of the standoff / post insulator type. Thru-bushing insulators may or may not be used at the
insulator compartment / penthouse and switch housing penetrations. Ground and/or disconnect switches may be part of the HV
bus arrangement.
HIGH VOLTAGE CONDUCTORS: Conductor to transmit the high voltage from the transformer-rectifier to the precipitator high
voltage system.
HIGH VOLTAGE SELECTOR SWITCH: Is the means to selectively energize a separate bus section when more than one bus is
controlled by a TR Set. There are several methods of high voltage isolation, but all must be accomplished with the TR Set shut
down and properly locked out. One type of switch is internal to the transformer and immersed in the same oil as the transformer
winding. Another type of switch, external to the TR tank, isolates the high voltage circuit with a blade mechanism by withdrawing a
blade from a clip or pan disc. A third mode of isolation on the high voltage side involves actual disconnection of a flexible lead from
one TR output bushing and physically placing a jumper between the two bushings (if one is not already in place).
HOPPERS: Hoppers located at the bottom of the precipitator casing and are used to collect the material that has been collected
and that falls off of the internal components that are cleaned. The typical shape is pyramidal with the sides of each hopper being
steep sloped and the outlet opening is sized so that fly ash may be easily removed by an ash removal system. Baffles are usually
placed in the hoppers; they extend below the dust level to minimize undesirable gas sneakage below the collection plates. Typically
hopper are equipped with level detectors to alarm high levels and hopper heaters which are used to reduce corrosion and to keep
the material fluidized. Hoppers are also equipped with access doors, strike plates for manually rapping the hopper walls, and poke
HOPPER CAPACITY: Total volumetric capacity of hoppers measured from a plane 10 below high voltage system or plates,
whichever is lower.
HOT SIDE ESP: An ESP which is installed upstream of the air heaters.
HOT WIRE ANEMOMETER: A device used for the measurement of flow velocities and turbulence in an ESP and its associated
ductwork. It has the advantage of high sensitivity at very low velocities and produces an electrical readout.
HUMIDITY, ABSOLUTE: The weight of water vapor per unit volume, pounds per cubic foot or grams per cubic centimeter.
HUMIDITY, RELATIVE: The ratio of the actual partial pressure of water vapor in a space to the saturated pressure of pure water
vapor in a space to the saturated pressure of pure water at the same temperature.
INLET DUST LOADING: A measure of the particulate matter entering an ESP expressed in grains of particulate matter per actual
IONS: Generally refers to the flue gas molecules within the gas passage that become primarily charged negatively by the action of
free electrons initiated from the CORONA DISCHARGE. It is this ionic flow that basically charges and pushes the ash particles
toward the positive ground COLLECTING SURFACE under the influence of the VOLTAGE FIELD. In the complex action of the gas
space, some positive gas ions are also formed which tend to promote particle deposition on the negative discharge electrode.
Negative ions by far are the most numerous in the gas space and help constitute a space charge in the precipitation process.
IN SITU RESISTIVITY: Particle resistivity as determined by a probe inserted into the flue gas stream. See Resistivity
INSULATOR COMPARTMENT: Enclosure for the insulator(s) supporting the high voltage system (may contain one or more
LAER (Lowest Achievable Emission Rate): The rate of emissions which reflects either the most stringent emission limit contained in
the implementation plan of any state (unless it is proved that such limitations are not achievable) or the most stringent emission
LINEAR REACTOR (CLR): This is primarily a ballast of inductance placed in the low voltage circuit to provide current limiting ability
under sparkover in the ESP. Another major advantage of a properly sized reactor is to better shape the waveform of the input
voltage to the TR Set thereby gaining a greater conduction angle of secondary current flow. This feature has benefits for ash or
KEY INTERLOCK SYSTEM: A system of locks that prevents opening the ESP access doors while the precipitator is energized.
MACT (Maximum Achievable Control Technology): The standard with which source of HAPs will have to comply; the CAAA defines
MACT as œthe maximum degree of reduction in emissions¦ achievable for new or existing sources¦ taking into account the cost of
achieving such reductions. MACT standards for existing sources must be at least as stringent as the average level of control
achieved at the best controlled 12 percent of facilities, and MACT for new sources will have to be even stricter.
MANUAL MODE: This refers to the ability to remove the automatic voltage control features from the electrical circuit by a switch
in the control cabinet. In this mode, the amount of power input to the ESP is fixed at the manual setting chosen. If excessive
sparkover occurs at this manual setting the control will not recognize nor correct this condition. This could cause deterioration in
MECHANICAL COLLECTOR: Devices that are functionally dependent on the laws of mechanics governing the motion of bodies in
space. They can be operated dry or wet. When operated wet, devices are generally called scrubbers. Examples of mechanical
collectors are cyclones, settling chambers and various types of impingement collectors.
MECHANICAL RECTIFIER: A device consisting of a disc or arms with appropriately placed contacts rotating at a synchronous speed
MIGRATION VELOCITY: A parameter in the Deutsch-Anderson equation used to determine the required size of an electrostatic
precipitator to meet specified design conditions. Other terminology used are œW value and precipitation rate. Values are generally
NOX (Nitrogen Oxides): Chemical compounds containing nitrogen and oxygen; react with volatile organic compounds, in the
presence of heat and sunlight, to form ozone. They are also a major precursor to acid rain. Nationwide, approximately 45% of NOX
emissions come from mobile sources, 35% from electric utilities and 15% from industrial fuel combustion.
OHMS LAW: The formula used to determine the relationship between Voltage (V), Current (I) and Resistance (R). V = IR
OPACITY: Refers to the amount of light that can pass through expressed in percent reduction of light intensity. At the stack it
normally refers to the degree of visibility of an exhaust plume. Normally measured by opacity monitors mounted in the ductwork
OZONE: A compound consisting of three oxygen atoms that is the primary constituent of smog. It is formed through chemical
reactions in the atmosphere involving volatile organic compounds, nitrogen oxides and sunlight. Ozone can initiate damage to the
lungs as well as damage to trees, crops and materials. There is a natural layer of ozone in the upper atmosphere, which shields the
PARTICLE SIZE: The diameter in mms (micrometers) of a particular piece of particulate matter.
PENTHOUSE: A weatherproof gas-tight enclosure over the precipitator to contain the high voltage insulators.
PIGGY-BACK LAYOUT: Refers to the orientation of two or more parallel ESPs in a piggy back arrangement (one on top of the other).
PITOT TUBE: A common instrument used for velocity determination in ducts leading to and from air pollution control devices.
PM 10: A EPA standard for measuring the amount of solid or liquid matter suspended in the atmosphere (œparticulate matter).
Refers to the amount of particulate matter under 10 micrometers in diameter. The smaller PM10 particles penetrate to the deeper
portions of the lung, affecting sensitive population groups such as children and people with respiratory diseases.
PM 2.5: New EPA standard that limits the amount of particulate matter emissions under 2.5 micrometers in diameter.
PPM (Parts Per Million): The number of parts of a given pollutant in a million parts of air. Units are expressed by weight or volume.
PRECIPITATOR CURRENT: The rectifier or unidirectional average current to the precipitator measured by a milliamp meter in the
PRECIPITATOR DIMENSIONS:
1. Effective Length: Total length of collecting surface measured in the direction of gas flow. Length between fields is to be
excluded.
2. Effective Height: Total height of collecting surface measured from top to bottom.
3. Effective Width: Total number of gas passages multiplied by spacing dimension of the collecting surface.
PRECIPITATOR VOLTAGE: The average DC voltage between the high voltage system and grounded side of the precipitator.
PREVENTATIVE MAINTENANCE (PM): This includes the actions that detect, preclude, or mitigate degradation of functional
equipment to sustain or extend its useful life by controlling degradation and failures to an acceptable level. There are three types
PERIODIC MAINTENANCE: is a form of preventive maintenance consisting of servicing, parts replacement, surveillance, or testing
PREDICTIVE MAINTENANCE: is a form of preventive maintenance performed continuously or at intervals governed by observed
condition to monitor, diagnose, or trend the equipment’s functional or condition indicators. Results indicate current and future
PLANNED MAINTENANCE: is a form of preventive maintenance consisting of refurbishment or replacement that is scheduled and
CORRECTIVE MAINTENANCE: includes actions that restore, by repair, overhaul, or replacement, the capability of any failed
PRIMARY AMMETER: This meter measures the current flow through the low voltage primary winding of the TR Set in alternating
current amperes. The meter normally receives its signal from a current transformer in the primary circuit. Dividing this indicated
current by the turns-ratio of the TR Set will provide the level of AC current in the secondary winding.
PRIMARY VOLTAGE: The voltage as indicated by an AC voltmeter across the primary of the transformer.
PRIMARY VOLTMETER: This meter measures the voltage drop across the primary winding of the high voltage transformer in the TR
Set. The voltage can be measured in various manners, but the object is not to include any other equipment or apparatus within the
measurement point located at the main power cables going directly to the TR Set. With recent SCR controls, the true value of this
current. Without actual secondary circuit meters, an approximate DC power input in watts would be between 65 to 70% of the
primary AC circuit volt-amperes. A key point here is not to rely on power as the criterion of good precipitation. Good precipitation
requires adequate VOLTAGE FIELDS; the current observed will be a reflection of many factors. Thus, we have to evaluate the values
of proper power input more in terms of how the voltage relates to the current than by the product of the two terms.
RACT (Reasonably Available Control Technology): An emission limitation on existing sources in nonattainment areas, defined by
EPA in a Control Techniques Guideline (CTG) and adopted and implemented by states. Under Title I of the CAAA, EPA will establish
RAPPERS – COLLECTING SURFACES: These are devices, generally located at the top of the ESP or bottom of the collecting plates,
which periodically impart a shock to the collecting surfaces to help dislodge the collected material into the hopper system. The
final collection efficiency of the precipitator is often determined by how well this process is conducted. The object is to dislodge
the material from the collector surface in small clumps or patches without building excessive dust layer thicknesses. This is a
complex part of precipitation, but it is more important to know that reliability of rapper operation holds priority over timing,
RAPPERS – HIGH VOLTAGE: These rapper devices impart a vibration or shock to the high voltage frame supporting the discharge
electrodes. The object is to keep the buildups on these electrodes from affecting the corona discharge pattern. The discharge
electrodes will generally exhibit irregular coatings of various size and shape. Whether the buildups observed during outage
inspections are detrimental can usually be determined by an analysis of electrical readings during periods of operation. It is usually
better to operate with some buildup than employ excessive rapping forces that can result in failure of DISCHARGE ELECTRODES.
RAPPER INSULATOR: A device to electrically isolate discharge electrode rappers yet transmit mechanically, forces necessary to
RAPPING INTENSITY: The œg force measured at various points on collecting or discharge electrodes. Measured forces should be
REENTRAINMENT: Re-entrainment, usually is associated with rapper re-entrainment, which refers to the reintroduction of
particulate back into to the gas stream from the discharge electrodes and collecting surfaces during rapping. Re-entrainment can
also result from gas sweepage when gases bypass the treatment zone of the ESP and disturb collection zones such as hoppers. High
velocity zones and external influences, such as ambient air infiltration of the casing or hopper, can also promote particulate re-
RESISTIVITY: This term is most critical for the fly ash precipitator because it directly controls the levels of voltage and current
observed at most installations. Resistivity refers to the electrical resistance of the ash layer after it forms on the positive ground
COLLECTING SURFACE. If the resistance level is high, the corona current passing through the ash layer must be generally reduced or
BACK CORONA effects will reduce performance of the ESP. The range of resistivity is primarily affected by the chemistry of the ash,
moisture in the flue gas, levels of sulfur trioxide, and flue gas temperature. Resistivity effects are generally observed by the
occurrence of SPARKOVER on most ESP fields at some reduced level of voltage and current. Operation in a good zone of resistivity
allows the ash layer on the collector plate to bond sufficiently for optimum ESP performance and helps to reduce
REENTRAINMENT. When resistivity drops to low levels, the ash layer on the collecting surface allows current to flow through it
without restriction and it is easily re-entrained back into the gas stream. This condition is generally characterized by high corona
RIGID DISCHARGE ELECTRODE (RDE) DESIGN: This term refers to precipitators utilizing rigid discharge electrodes, such as the pipe
and spike variety, for its discharge electrode rather than a weighted wire type of high voltage system.
RIGID FRAME DESIGN: This term refers to precipitators utilizing rigid frames with tensioned discharge electrodes between
supporting members. Frame shapes can vary from rectangular tubular pipes with horizontal cross members to Mast frames with a
vertical primary support and horizontal cross members in a T configuration. Electrode styles and shapes can also vary widely. Rigid
frame designs are almost exclusive to European design precipitators and are typically rapped by tumbling hammer rappers located
SAFETY GROUNDING DEVICE: A device for physically grounding the high voltage system prior to personnel entering the
precipitator. (The most common type consists of a conductor, one end of which is grounded to the casing, the other and attached
SATURABLE CORE REACTOR: This is a method of voltage control for the precipitator that has been superseded in recent years by
the SCR. The saturable core reactor passed the primary current through a substantial winding on an iron core. The voltage output
of this device varied by the level of DC current through a control winding and its subsequent effect on the saturation flux of the
reactor core. This control was used extensively for years and still exists at some locations. A disadvantage was a slower response to
sparkover conditions.
SCA (Specific Collecting Area): The quotient of the total collecting area (A) divide by the total gas volume (V) handled by the ESP
SPECIFIC COLLECTING AREA (SCA): A figure obtained by dividing total effective collecting surface of the precipitator by gas volume,
SPECIFIC CORONA POWER: The quotient of the total corona power of all precipitator bus sections divided by the total gas volume
handled by the precipitator, multiplied by 1000 Units are expressed as watts/1000 acfm.
SCFM (Standard Cubic Feet Per Minute): The volume that a gas would occupy at standard temperature and pressure conditions
SCR: Selective Catalytic Reduction is the most advanced and efficient process for NOx reduction. SCR technology is based upon the
conversion (reduction) of NOx (NO2 and NO) with ammonia (NH3) into water (H2O) and nitrogen (N2). A catalyst is used to speed
up the conversion rate. The term SCR is used to describe both for the technology and the apparatus that that is used.
SCR CONTROLS (Silicon-Controlled Rectifier): Silicon controlled rectifiers are the most extensively used method of voltage control
in recent years, and consists of two silicon rectifiers mounted in an inverse parallel fashion in the primary AC circuit of the TR Set.
Thyristors are also used instead of silicon diodes, but the principle is basically identical. These devices are normally open in both
directions until a small gate signal is applied which allows the SCR to conduct in one direction. The output is controlled by the
strength of the current flow in the gate circuit which receives it’s signal from either the AUTOMATIC or MANUAL mode operation
SCRUBBER: A device that uses a liquid spray to remove aerosol and gaseous pollutants from an air stream. The gases are removed
either by absorption or chemical reaction. Solid and liquid particulates are removed through contact with the spray. Scrubbers are
SECONDARY AMMETER: This meter measures the average DC secondary current, which is actually the precipitator corona current
passing through the ground path on its return to the rectifier connection of the TR Set so as to complete the electrical circuit. This
meter has a low resistance movement and the scale reads in milliamperes or amps depending on the size of the TR Set. The
secondary current waveform can usually be observed by connecting an oscilloscope across the meter. There is usually a shorting
device or surge arrestor across the meter for protection. Under no circumstance should the leads be removed from this type of
meter with the TR set energized. Another method generally used is a meter measuring a voltage across a resistor and calibrated as
a current meter.
SECONDARY VOLTMETER: This measurement is made between the rectifier output and the outlet bushing of the TR Set by use of a
voltage divider installed inside the tank. With older TR Sets, it is possible to obtain the average precipitator voltage, usually read as
average DC kilovolts, by installation of a retrofit voltage divider at the outlet bushing of the TR Set. The indicated voltage
represents the voltage from the discharge electrode to ground, comprising both the voltage drop across the gas space as well as
the ash layer on the collecting surface. It actually is a measurement of the dielectric resistance and represents all the
SHROUD: Refers to a steel tube or rod installed at the top and bottom of a wire discharge electrode. The purpose of this shroud,
approximately 3/8″ (9.5mm) outside diameter, is to eliminate the corona discharge opposite the top and bottom termination of
the collector plate. The enlarged radius of the shroud would require a higher voltage than required by the wire to initiate a corona
tuft. The shrouds usually extend about 4 – 6 inches (102 – 152mm) into the gas passage. Prevention of localized sparkover at these
SILICON DIODE BRIDGE: The diode assembly converts the high voltage AC to DC voltage. These bridges are normally made up
individual diodes connected in series. The number of diodes used will vary by manufacturer from 20 to several hundred.
SNCR (Selective Non-Catalytic Reduction): As the name implies this form of NOx reduction technology does not use a catalyst as
with SCR NOx reduction technology. With the SNCR technology, ammonia or ammonia-based compounds, such as urea, are
injected into the furnace at specific temperatures. These temperatures are much higher than those for an SCR, the optimum being
around 1400 to 2000 F. The NOx reduction reactions are very sensitive to temperature and ammonia slip is a common problem.
SO2: Sulfur dioxide is an invisible, nonflammable acidic gas, formed during combustion of fuel containing sulfur.
SO3: Sulfur trioxide oxidized from SO2; combines with atmospheric moisture to form sulfuric acid mist (H2SO4).
SPARKOVER: Is a localized electrical breakdown in the gas space between the high voltage system and ground. This generally
occurs between the DISCHARGE ELECTRODE and COLLECTING SURFACE. This breakdown, or flashover, can occur when the physical
clearance has been reduced so that the operating voltage is greater than the space will allow. More often, sparkover will occur
when the resistivity of the ash layer on the collecting surface reaches critical levels. Premature sparkover at extreme low levels of
voltage can often be observed with a combination of higher resistivity and internal difficulties such as reduced electrical
clearances.
During a significant sparkover, the basic collapse of the VOLTAGE FIELD occurs which should always cause a downward flick of the
VOLTMETER needles. A small number of sparks per minute is generally desirable in fly ash precipitators as long as it occurs at
SPARKMETER: This meter attempts to represent the number of sparks per minute by integrating these transient surges by some
type of capacitance circuit. In most locations where spark-meters still exist, replacement of the automatic voltage controls will
discontinue its use. In all cases, representation of the ESP sparkover by a meter can be misleading. For all practical purposes, it is
recommended that a visual count or evaluation of the flicks of the voltmeter needle be made on a per minute basis to better gauge
the spark rate. Spark rates as high as 60 to 70 per minute can be easily observed. This is generally at the higher range that should
exist on most modern installations. At this higher sparkover level, the meter needle must still come to rest many times during any
given minute.
STRUCTURAL STEEL: The precipitator casing is support by a structure steel system that is typically only tied to the ESP in one fixed
___location to allow the ESP casing to grow and expand independently during normal operation. The casing columns rest on a slide
SUPPORT INSULATOR: This term refers to the ceramic component that supports and isolates the high voltage frame from ground
potential. Recent designs involve an alumina cylinder that also acts as a gas seal at the top frame locations. The surface of the
insulator is sensitive to electrical leakage to ground if condensation or contamination is allowed to occur. Purge air and heater
TR RATING: The transformer – rectifier (TR) should be sized to supply sufficient current for the area of the precipitator to which it
is connected. The nameplate shows a KVA size, primary and secondary voltage ratings, and primary and secondary current ratings.
These values are of most interest. The nameplate should show whether the primary winding is tapped for more than one voltage
connection. A key point here is that the actual electrical performance of the ESP may in no way resemble any of the values shown
on the nameplate.
TR SET: Is the term for the high voltage transformer and rectifier that provides the electrical energy for a given precipitator area.
These components involve a specially wound transformer that supplies a RMS secondary voltage sized on the basis of GAS
PASSAGE spacing and discharge electrode design. An RMS secondary voltage of about 53,500 volts AC (45 KV DC average) is utilized
for the 9″ (228mm) wide GAS PASSAGE of most weighted wire precipitators; 77,300 volts AC (65 KV DC average) for most of the
specified at the 45,000 – 50,000 volt level for 9″-10″ (228 – 254mm) plate spacing; the 55,000 – 65,000 volt level for 11″-12″ (279 –
305mm) plate spacing; the 70,000 – 90,000 volt level for 15″-16″ plate spacing. Other pertinent data can be observed on the metal
nameplate of each tank. While the voltages are generally similar between TR Sets, the current ratings vary greatly based on the
anticipated load requirements of the particular ESP FIELD. While the KVA rating is used, it is also common practice to specify the
TR TURNS RATIO: Expresses the number of turns in the secondary winding of the transformer for every turn in the primary
winding. For example, a TR Set with a 400 volt primary rating relative to a 53,500 volt secondary would have an approximate ratio
TRANSITION: An aerodynamically designed inlet or outlet duct connection to the precipitator. Transitions are normally included as
TREATMENT TIME: A figure, in seconds, obtained by dividing the effective length, in feet, of a precipitator by the precipitator gas
TURNING VANES: Vanes in ductwork or transition to guide the gas and dust flow through the ductwork in order to minimize
pressure drop and to control the velocity and dust concentration contours.
V-I CURVE: Usually refers to a plot of secondary voltage versus secondary current for a single TR set in which the shape of the
plotted curve might indicate a number of internal operating characteristics of the precipitator. An important part of these
measurements is the indicated voltage at the threshold of corona current. While normally obtained during air load, these curves
VOLTAGE DIVIDER: A means for supplying a low voltage feedback signal that is proportional to the KV output of the TR.
VOLTAGE FIELD: Refers to the high voltage field generated between the negative discharge electrode and positive collecting
surface at ground potential. This field supplies the charging mechanism and driving force for the removal of the particles from the
flue gas stream. Desirable values of this field strength would lie between 4 to 5 kilovolts per inch of space.
VOLTAGE WAVE SHAPE: The pulsating DC voltage in the precipitator will show peak and minimum values that vary in magnitude
about the average as observed on a secondary KV meter. The peak voltage is based somewhat on the peak AC magnitude while the
minimum voltage is based on the capacitance resistance effect on the decay characteristics of the voltage field in the gas passage.
The conduction time of the secondary current will be a factor. With low capacitance conditions, the minimum point might coincide
WEATHER ENCLOSURE:
Upper Weather Enclosure “ A non gas-tight enclosure on the roof of the precipitator to shelter equipment (TR sets, rappers,
WEIGHTS: This term refers to the cast iron weight attached to the bottom of the wire discharge electrode to keep it taut, much like
the effect of a plumb-bob. These weights are about 25 lbs. (11.3kg) for most installations. The weights are positioned and retained
in a bottom guide frame for maintenance of wire alignment at the center line of the gas passage.
WEIGHTED WIRE DESIGN: This term refers to precipitators utilizing the wire and weight for its discharge electrode rather than a